1 3 of 3.
Knauf full fill cavity wall insulation.
With bca thermal regulations becoming more stringent and home owners demanding increased comfort and energy efficiency dritherm cavity slab provides a simple cost effective insulation option for home designs requiring 6 star compliance.
Knauf insulation ltd po box 10 stafford road st helens merseyside wa10 3ns.
Fully filling the cavity prevents mortar snots and other debris falling into the cavity preventing bridges that can serve as a path for water to track from the outer to inner leaf.
Lambda λ w mk 0 035 0 037.
In addition to thermal performance fire performance of insulation materials is a crucial consideration particularly when designing buildings over 18m in height or when the building is to have.
Euroclass reaction to fire a1.
The installer will use a design pattern to drill holes into the external wall and then fill the cavity space with loose glasswool insulation.
Thickness range mm 50 150.
The installation is quick and clean and will generally only take a couple of hours to install by an approved installer.
The best solution to retrofit cavity walls is to hire an approved installer.
Full fill built in solutions are installed as the walls are built whilst full fill blown in solutions are installed once walls are built and when the building is watertight.
B r 15 r 19 shall be permitted to be met with r 13 cavity insulation on the interior of the basement wall plus r 5 continuous insulated sheathing on the interior or exterior of the home.
Masonry cavity slabs are manufactured to 455mm widths to suit standard wall tie spacing reducing the need to cut slabs to size on site.
Either insulation meets the requirement.
The cavity between the insulation and the outer leaf performs as a barrier to external moisture preventing it from tracking to the inner construction.
Blown in mineral wool provides a full fill solution even if walls are built out of tolerance reducing the risk of unwanted heat loss.
Masonry cavity slabs have a water repellent additive and are designed for use in external masonry cavity walls up to 25m to provide a full fill insulation solution which is installed as walls are being built.
Dritherm cavity slab is 600mm wide to suit standard vertical wall tie spacings ensuring a closed joint with adjacent slabs.
Find your local website insulating pre fabricated homes is now faster and easier than ever thanks to knauf insulation s innovative new supafil max frame system.
A the first r value applies to continuous insulation the second to framing cavity insulation.
For more information talk to us today by calling 01744 766600.
Slabs fully fill the cavity and knit together at joints preventing air movement and infiltration through or around the insulation slabs are installed under compression preventing moisture penetration and cold bridging at joints low cost quick and easy to install masonry cavity walls full fill with built in glass mineral wool.
Dritherm cavity slab can be used in masonry cavity external walls and is installed to fully fill the cavity.